Technical Information
|
Measurement Range* |
4–20 mA |
Accuracy |
± 0.1 mA (± 0.5% full scale) over full temperature range of -40°C to 75°C (-40°F to 167°F) |
Resolution |
±4.93 µA |
Input Impedance |
124 Ω |
Switched Input |
Maximum switch voltage above ground (Pin 2 to Pin 1): 20 V Maximum switch current: 50 mA On time: 316.6 ms ±3% |
Sensor Trigger: Source |
Voltage: 2.5 V ±2.4%; maximum current: 1 mA On time: 12.7 ms ±3% |
Operating Temperature Range |
-40°C to 75°C (-40°F to 167°F) |
Housing |
Plastic case; must be placed inside logger enclosure to protect from direct exposure to the weather |
User Connection |
Six-position screw terminal strip (16–30AWG); shielded cable recommended with outside diameter of 3.2 to 3.8 mm (0.125 to 0.150 in.) |
Dimensions |
4.5 x 4.8 x 1.6 cm (1.8 x 1.9 x 0.6 in.) |
Weight |
25 g (0.88 oz) |
Number of Data Channels** |
1 |
Measurement Averaging Option |
Yes |
Digital Filtering |
Automatic digital filtering with 32 readings/sample in 16.6 ms |
Bits per Sample |
12 |
Length of Smart Sensor Network Cable** |
14 cm (5.5 in.) |
|