Search
Menu Close

HOBO Concrete Curing Temperature Data Logger Kit

Manufacturer:
The Concrete curing temperature data logger kit includes everything you need to start logging the temperature curing process of concrete.
Part Number: Concrete-Kit
Back to Previous Page
$0.00 ex GST
i h

Achieve Optimal Curing Temperatures Instantly with This Solution

The Concrete curing temperature data logger kit includes everything you need to start logging the temperature curing process of concrete.


This kit includes

1 x UX120-014M 4 Channel Thermocouple Data Logger
1 x CABLE-USBMB USB Cable from Logger to PC.
1 x HB6412 Logger Box Waterproof data logger enclosure
4 x CONCRETE-K-10M, 10m Ready-made Thermocouples complete Miniplugs and 10 extra crimp ferrules so you can cut the used sensor off after the cure and re-use it on the next job.
HOBOware software is a free download from our web site: Here


The HOBO UX120 Thermocouple Logger is a four-channel LCD data logger for measuring and recording temperature and accepts 4 type K temperature sensors via a mini plug.

In addition to accepting four thermocouple probes, the logger features an internal temperature sensor for logging ambient temperatures, further extending the range of capabilities.

The supplied Enclosure is fitted with 4 x Cable Glands for the thermocouple leads and back hooks for storing long cables, standing the box upright or hooking to framework.
This Enclosure has an IP66 Rating (with all glands sealed) and a Transparent cover to see the data logger display.
175(L) x 125(W) x 75(D)mm


Note: Minor assembly required.
The logger is fixed to the metal backing plate with inbuilt magnets
Thermocouples thread through fitted cable glands and plug into the logger.


Monitoring Concrete Curing Temperatures with Data Loggers

Monitoring Concrete Curing Temperatures with Data Loggers

Learn the importance of monitoring concrete curing temperatures, and the potential consequences of not doing so.

Technical Information

Thermocouple

Type Range Accuracy Resolution
J -210° to 760°C
(-346° to 1,400°F)
±0.6°C (±1.08°F) ± thermocouple
probe accuracy
0.03°C (0.06°F) 
K -260° to 1,370°C
(-436° to 2,498°F)
±0.7°C (±1.26°F) ± thermocouple
probe accuracy
0.04°C (0.07°F) 
T -260° to 400°C
(-436° to 752°F)
±0.6°C (±1.08°F) ± thermocouple
probe accuracy
0.02°C (0.03°F)
E -260° to 950°C
(-436° to 1,742°F)
±0.6°C (±1.08°F) ± thermocouple
probe accuracy
0.03°C at (0.05°F)
R -50° to 1,550°C
(-58° to 2,822°F)
±2.2°C (±3.96°F) ± thermocouple
probe accuracy
0.08°C (0.15°F) 
S -50° to 1,720°C
(-58° to 3,128°F)
±2.2°C (±3.96°F) ± thermocouple
probe accuracy
0.08°C (0.15°F) 
B 550° to 1,820°C
(1,022° to 3,308°F)
±2.5°C (±4.5°F) ± thermocouple
probe accuracy
0.1°C (0.18F) 
N -260° to 1,300°C
(-436° to 2,372°F)
±1.0°C (±1.8°F) ± thermocouple
probe accuracy
0.06°C (0.11°F)

Internal 10K Thermistor (Temperature)

Range -20° to 70°C (-4° to 158°F)
Accuracy ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F), see Plot A of User Manual
resolution 0.024°C at 25°C (0.04°F at 77°F); see Plot A of User Manual
Drift <0.1°C (0.18°F) per year

Logger

Logger Operating Range Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing);
Launch/Readout: 0° to 50°C (32° to 122°F) per USB specification
Loggnig Rate 1 second to 18 hours, 12 minutes, 15 seconds
Logging Modes Fixed interval (normal), burst, or statistics
Memory Modes Wrap when full or stop when full
Start Modes Immediate, push button, date & time, or next interval
Stop Modes When memory full, push button, or date & time
Restart Mode Push button
TIme Accuracy ±1 minute per month at 25°C (77°F), see Plot B of User Manual
Power Source Two AAA 1.5 V alkaline batteries, user replaceable, and USB cable
Battery Life 1 year, typical with logging rate of 1 minute and sampling interval of
15 seconds or greater
Memory 4 MB (1.6 million measurements, maximum) 
Download Type USB 2.0 interface
Full Memory Download Time Approximately 1.5 minutes
LCD LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly
or go blank in temperatures outside this range
Size 10.8 x 5.41 x 2.54 cm (4.25 x 2.13 x 1 in.) 
Weight 107.5 g (3.79 oz) 
Environmental Rating IP50
CE The CE Marking identifies this product as complying with all relevant
directives in the European Union (EU).

HOBOware Software

HOBOware software is used for launching, reading out, and plotting data from HOBO® data loggers. With HOBOware, you can also check logger status, filter and export data, save changes to graphs in project files, and scale data with the Linear Scaling and Pulse Scaling data assistants. There are two versions of HOBOware: HOBOware and HOBOware Pro.


HOBOware Standard features

  • Simple menus for fast, easy logger setup and readout
  • Point & click for fast setup and readout
  • Scaling to real-world engineering units
  • Presentation-quality graphs
  • Easy export of data files to text or Excel format

FREE DOWNLOAD


Learn more about HOBOware and HOBOware-Pro Features >>


IMPORTANT: This HOBO data logger requires HOBOware software and a communications cable (see related products below)


Achieve Optimal Curing Temperatures Instantly with This Solution

The Concrete curing temperature data logger kit includes everything you need to start logging the temperature curing process of concrete.


This kit includes

1 x UX120-014M 4 Channel Thermocouple Data Logger
1 x CABLE-USBMB USB Cable from Logger to PC.
1 x HB6412 Logger Box Waterproof data logger enclosure
4 x CONCRETE-K-10M, 10m Ready-made Thermocouples complete Miniplugs and 10 extra crimp ferrules so you can cut the used sensor off after the cure and re-use it on the next job.
HOBOware software is a free download from our web site: Here


The HOBO UX120 Thermocouple Logger is a four-channel LCD data logger for measuring and recording temperature and accepts 4 type K temperature sensors via a mini plug.

In addition to accepting four thermocouple probes, the logger features an internal temperature sensor for logging ambient temperatures, further extending the range of capabilities.

The supplied Enclosure is fitted with 4 x Cable Glands for the thermocouple leads and back hooks for storing long cables, standing the box upright or hooking to framework.
This Enclosure has an IP66 Rating (with all glands sealed) and a Transparent cover to see the data logger display.
175(L) x 125(W) x 75(D)mm


Note: Minor assembly required.
The logger is fixed to the metal backing plate with inbuilt magnets
Thermocouples thread through fitted cable glands and plug into the logger.


Monitoring Concrete Curing Temperatures with Data Loggers

Customers who bought this item also bought

HOBO - 4-Channel Pulse Data Loggers

The HOBO UX120 Pulse Logger is a highly versatile, 4-channel energy data logger that combines the functionality of four separate data loggers into one compact unit. It enables energy management professionals – from energy auditors to building commissioners – to easily track building energy consumption, equipment runtimes, and water and gas flow rates.
$442.00 (ex gst)

HOBO USB Cable - for U Series Loggers

This USB logger-to-PC communications cable is six feet long and coated in black plastic
$38.00 (ex gst)