The AC Voltage transmitter is a self-powered transformer for monitoring sine wave and single-phase AC voltage. Available in two ranges: 0 to 150 Volts AC, and 0 to 300 Volts AC.

Requirements for use with specific data loggers:

  • HOBO MX1100 series: a 4-20mA input cable (SD-MA-420)
  • HOBO U12, UX120-006M, or ZW series: a 4-20mA input cable (CABLE-4-20mA)


Features

  • Available in 2 ranges: 0 to 150 & 0 to 300 Volts AC
  • Requires an input cable (part # CABLE-4-20mA)


Important Information

Refer to data logger product pages to ensure you have the proper interfaces (modules, adapter, etc.) to deploy this sensor.

Technical Information

Ranges 0-150 and 0-300 volts RMS
Sensor Accuracy < ±0.1% of span (20% to 120% of range) ±0.25% of span (10% of range)
Over Range +20% of span
Over Load +40% of span
Frequency 60 Hz AC
Supply Self-powered
Output 0–20 mA
Response time to 90% <240 msec
Operating conditions -20° to 70°C (-4° to 158°F); 5-95% RH, non-condensing
Housing Plastic Carbonate

Protection Level

Box According to IP-50 DIN 40050
Terminals According to IP-10 DIN 40050
Mounting Standard 35mm DIN rail

Notes: Because these sensors tie directly into the line, they should be used only by qualified personnel.


Requirements

For U12 & H8 Loggers: Input Cable (Part # CABLE-4-20mA)
For HOBO Energy Logger: FlexSmart Analog Module (Part # S-FS-CVIA)

The AC Voltage transmitter is a self-powered transformer for monitoring sine wave and single-phase AC voltage. Available in two ranges: 0 to 150 Volts AC, and 0 to 300 Volts AC.

Requirements for use with specific data loggers:

  • HOBO MX1100 series: a 4-20mA input cable (SD-MA-420)
  • HOBO U12, UX120-006M, or ZW series: a 4-20mA input cable (CABLE-4-20mA)


Features

  • Available in 2 ranges: 0 to 150 & 0 to 300 Volts AC
  • Requires an input cable (part # CABLE-4-20mA)


Important Information