HOBO MX2500 - Replacement Electrode

Manufacturer:
This plastic-bodied electrode and the HOBO MX2501 pH and Temperature Data Logger are perfectly suited for environmental monitoring of streams, lakes, rivers, estuaries, and oceans.
Part Number: MX2500-ELECTRODE
Back to Previous Page
$375.00 ex GST
i h

With its gel electrolyte and double Pellon® junction minimizing the chance of contamination of the reference electrolyte, this plastic-bodied electrode and the HOBO MX2501 pH and Temperature Data Logger are perfectly suited for environmental monitoring of streams, lakes, rivers, estuaries, and oceans. The electrode uses potentiometric and temperature measurements of samples to determine the pH, and can easily be replaced because of the simple plug-and-play 3.5-mm connector. Following proper calibration, storage, and maintenance protocols for the electrode, the MX2501 can achieve pH accuracies of ±0.10 pH units within ±10°C of temperature at calibration.

The replacement pH electrode replaces the original pH electrode that ships with the HOBO MX2501 logger. The electrodes should be replaced after six months of use.

Note: pH electrodes should always be kept in storage solution when not deployed.


Introducing - Onset HOBO pH and Temperature Data Logger

This video introduces the HOBO® MX2501 pH and Temperature Logger for long-term monitoring of pH in aquatic environments. The logger communicates wirelessly via Bluetooth Low Energy (BLE) to the HOBOmobile® app on a phone or tablet, making logger setup, calibration, and data offload quick and easy, with no need for extra equipment or complicated calibration procedures.



How to Calibrate the HOBO MX2501 pH and Temperature Data Logger

This video will guide you on how to properly calibrate the HOBO MX2501 Bluetooth pH and Temperature logger. Calibration is important to compensate for tolerances due to manufacturing, as well as for electrode aging, conditioning, and cleaning. It is also used to confirm the condition of the electrode.



How to Replace the pH Electrode on the HOBO MX2501 pH Logger

This video provides guidance on the proper method for replacing the pH electrode in an Onset HOBO MX2501 pH and temperature logger.



Webinar on Demand - HOBO pH and Temperature Loggers

This webinar reviews pH theory and introduces the HOBO® MX2501 pH and Temperature Logger for long-term monitoring of pH in aquatic environments. The logger communicates wirelessly via Bluetooth Low Energy (BLE) to the HOBOmobile® app on your phone or tablet, making logger setup, calibration, and data offload quick and easy, with no need for extra equipment or complicated calibration procedures.


With its gel electrolyte and double Pellon® junction minimizing the chance of contamination of the reference electrolyte, this plastic-bodied electrode and the HOBO MX2501 pH and Temperature Data Logger are perfectly suited for environmental monitoring of streams, lakes, rivers, estuaries, and oceans. The electrode uses potentiometric and temperature measurements of samples to determine the pH, and can easily be replaced because of the simple plug-and-play 3.5-mm connector. Following proper calibration, storage, and maintenance protocols for the electrode, the MX2501 can achieve pH accuracies of ±0.10 pH units within ±10°C of temperature at calibration.

The replacement pH electrode replaces the original pH electrode that ships with the HOBO MX2501 logger. The electrodes should be replaced after six months of use.

Note: pH electrodes should always be kept in storage solution when not deployed.

Customers who bought this item also bought

HOBO - Replacement DO Sensor Cap

Replaces the original DO sensor cap that’s included with the HOBO DO Data Logger.
$322.00 (ex gst)