Search
Menu Close

VCP QRT 24-series - Room Air Quality (VOC) Transmitters

Manufacturer:
The room air quality transmitters QRT 24 series for the measurement of VOC's (Volatile Organic Compounds)
Part Number: QRT
Back to Previous Page
Product Files
$300.00 ex GST
i h

Room Air Quality (VOC) Transmitters QRT 24-series

The self-calibrating microprocessor-controlled room air quality transmitters QRT 24 series is used to determine the room air quality on basis of a mixed gas sensor / VOC sensor (VOC = Volatile Organic Compounds).

Room air quality is understood as subjective air quality, felt by human beings with their olfactory organs.

As perception varies from person to person and therefore, air quality is assessed differently, a general definition of criteria for room air quality is not possible.

By linearising and high operating temperatures, the air quality transmitter achieves marginal drift and good stability.

The sensor is automatically self-calibrating.

The air quality sensor does not trace the concentrations of individual gases, but assesses the mixed gas as such, i.e. gas concentrations are not measured selectively.

Therefore, it is not possible to specify gas concentrations by the unit ppm.

Detectable gases: mixed gas, vapours of alcanoles, cigarette smoke, automobile exhaust gases, exhaled breathing air, combustion smoke (from wood, paper, plastics).

In addition, compounds of alkanes, alkenes, aromats, terpenes, halogenated hydrocarbons, esters, aldehydes and ketones as well as native VOCs such as terpenes and isoprene are ranking among volatile organic compounds VOC.

VOCs also evaporate from chemical products used in construction such as coating compounds, adhesives, or sealing compounds, furnishing objects, cleaning and care products, office chemicals and floor carpeting.

The sensor’s service life is depending on the type of burden and gas concentration and is more than 60 months under normal load conditions.

The new design implies the alternative to choose between three sensibility ranges by means of DIP switches, comparable to three measuring ranges: LOW for low, MEDIUM (default, equivalent to the hitherto existing type of this device) for medium, and HIGH for high noxious gas contaminations.

QRT 24, standard version

0-10 Vdc or 4-20 mA or 0-20 mA output (selectable)
Potential free changeover contact as a switch output

QRT 24 L,

same as QRT 24 and with
“traffic light” 5 coloured LED´s indication of air quality (VOC)

QRT SS,

same as standard version QRT 24 but with
stainless steel enclosure for schools, military barracks and public buildings
Please contact us for pricing on the Stainless Steel Version

Room Air Quality (VOC) Transmitters QRT 24-series

The self-calibrating microprocessor-controlled room air quality transmitters QRT 24 series is used to determine the room air quality on basis of a mixed gas sensor / VOC sensor (VOC = Volatile Organic Compounds).

Room air quality is understood as subjective air quality, felt by human beings with their olfactory organs.

As perception varies from person to person and therefore, air quality is assessed differently, a general definition of criteria for room air quality is not possible.

By linearising and high operating temperatures, the air quality transmitter achieves marginal drift and good stability.

The sensor is automatically self-calibrating.

The air quality sensor does not trace the concentrations of individual gases, but assesses the mixed gas as such, i.e. gas concentrations are not measured selectively.

Therefore, it is not possible to specify gas concentrations by the unit ppm.

Detectable gases: mixed gas, vapours of alcanoles, cigarette smoke, automobile exhaust gases, exhaled breathing air, combustion smoke (from wood, paper, plastics).

In addition, compounds of alkanes, alkenes, aromats, terpenes, halogenated hydrocarbons, esters, aldehydes and ketones as well as native VOCs such as terpenes and isoprene are ranking among volatile organic compounds VOC.

VOCs also evaporate from chemical products used in construction such as coating compounds, adhesives, or sealing compounds, furnishing objects, cleaning and care products, office chemicals and floor carpeting.

The sensor’s service life is depending on the type of burden and gas concentration and is more than 60 months under normal load conditions.

The new design implies the alternative to choose between three sensibility ranges by means of DIP switches, comparable to three measuring ranges: LOW for low, MEDIUM (default, equivalent to the hitherto existing type of this device) for medium, and HIGH for high noxious gas contaminations.

QRT 24, standard version

0-10 Vdc or 4-20 mA or 0-20 mA output (selectable)
Potential free changeover contact as a switch output

QRT 24 L,

same as QRT 24 and with
“traffic light” 5 coloured LED´s indication of air quality (VOC)

QRT SS,

same as standard version QRT 24 but with
stainless steel enclosure for schools, military barracks and public buildings
Please contact us for pricing on the Stainless Steel Version